Guaranteed accuracy range:18~28ºC Under 80% RH MAX. No condensation
| Model |
DCM2000R |
DCM2000AD |
DCM2000 |
DCM600 |
Display Counts |
4000 |
4000 |
2000 |
2000 |
True RMS |
|
--- |
--- |
--- |
Conductor Size |
55mm |
55mm |
55mm |
40mm |
Frequency Response |
50/60Hz |
50/60Hz |
50/60Hz |
50/60Hz |
Withstand Voltage |
5550V AC |
5550V AC |
5550V AC |
5550V AC |
IEC1010 |
|
|
|
|
CE Marking |
|
|
|
|
ACA |
Accuracy |
1.50% |
1.50% |
1.20% |
1.50% |
Range |
40/400/
2000A |
40/400/
2000A |
20/200/
2000A |
20/200
/600A |
DCA |
Accuracy |
1.50% |
1.50% |
--- |
--- |
Range |
40/400
/2000A |
40/400
/2000A |
--- |
--- |
ACV |
Accuracy |
1.20% |
1.20% |
1.20% |
1.50% |
Range |
4/40/400/
600V |
4/40/400/
600V |
2/20/20/
600V |
20/200/
600V |
DCV |
Accuracy |
1.20% |
1.20% |
1.20% |
1.00% |
Range |
4/40/400/
600V |
4/40/400/
600V |
2/20/20/
600V |
20/200/
600V |
Ohm |
Accuracy |
1.50% |
1.50% |
1.50% |
1.50% |
Range |
400/4k/40k/400k
/4M/40M ohm |
400/4k/40k/400k
/4M/40M ohm |
200/2k/20k/220k
/2M20M ohm |
200/2k/20k/
2M/20M ohm |
Hz |
Accuracy |
0.50% |
0.50% |
--- |
--- |
Range |
100/1k/10k/
100k/1000k Hz |
100/1k/10k/
100k/1000k Hz |
--- |
--- |
Function |
Data Hold |
|
|
|
|
Diode Test |
|
|
|
|
Audible
Continuity |
|
|
|
|
Range
Hold |
|
|
--- |
--- |
Auto Power Off |
|
|
|
|
Max. Min
Hold |
|
|
--- |
--- |
Temperature |
--- |
--- |
--- |
--- |
| Model |
DCM10ADL |
DCM6L |
CAM600S |
CAM610R |
Display Counts |
2000 |
2000 |
Analog Pointer |
Analog Pointer |
True RMS |
--- |
--- |
--- |
|
Conductor Size |
40mm |
40mm |
36mm |
36mm |
Frequency Response |
50/60Hz |
50/60Hz |
50/60Hz |
50/60Hz |
Withstand Voltage |
5550V AC |
5550V AC |
5550V AC |
5550V AC |
IEC1010 |
|
|
|
|
CE Marking |
|
|
|
|
ACA |
Accuracy |
1.50% |
1.50% |
3.00% |
3.00% |
Range |
200/1000A |
200/600A |
6/15/60/
150/600A |
6/15/60/
150/600A |
DCA |
Accuracy |
1.50% |
--- |
--- |
--- |
Range |
200/1000A |
--- |
--- |
--- |
ACV |
Accuracy |
--- |
--- |
3.00% |
3.00% |
Range |
--- |
--- |
150/300/
600V |
150/300/
600V |
DCV |
Accuracy |
--- |
--- |
3.00% |
- |
Range |
--- |
--- |
60V |
- |
Ohm |
Accuracy |
--- |
--- |
3.00% |
3.00% |
Range |
--- |
--- |
1k/100k
ohm |
1k/100k
ohm |
Hz |
Accuracy |
--- |
--- |
--- |
--- |
Range |
--- |
--- |
--- |
--- |
Function |
Data Hold |
|
|
|
|
Diode Test |
|
--- |
--- |
--- |
Audible
Continuity |
--- |
--- |
--- |
--- |
Range
Hold |
--- |
--- |
--- |
--- |
Auto Power Off |
--- |
--- |
--- |
--- |
Max. Min
Hold |
--- |
--- |
--- |
--- |
Temperature |
--- |
--- |
--- |
--- |
|
Home
| About Us
| Products
| Telecom Systems
| Contact Us
| E-mail
Bhumika International Inc.
Ph: +1(416)
930 2931
E-mail: info@bhumika.ca
Website: http://www.bhumika.ca
Technical Specifications are subject to change without
notice.
Windows is the registered Trademark of Microsoft Corporation, USA.
All other trademarks are the ownership of their respective owners. |