1. Instruction Manual
2. Carrying case
3. Test lead
4. Battery 1.5V x 2


1. 40A/400A AC & DMM function (AC/DC, Ohm)
2. 4000 count & 42 segments analog bargraph
3. CT diameter size 29mm
4. Hz measurement by clamp of cords
5. Data hold function
6. Continuity Buzzer
7. Auto power off
8. Low battery indication
9. IEC 1010 600V CATII, 300V CATIII


Digital Display 3 3/4 digits LCD display with maximum reading 3999
Analog Display 42 segments fast analog bar display
Symbol and Scale range adjust automatically according range and input signal
Polarity When negative signal in apply to the tester, will show.
Over Load When the signal larger than the maximum will be show .
Sample Rate 2 times/sec for digital data
20 times/sec for analog bar
Low Power Indication When the battery is under the proper operation range, will appear on the LCD display.
Power Source UM-4 or AAA 1.5V battery x 2.
Auto Power Off If there is no key or dial operation for 30 minutes, the meter will power itself off to save battery consumption.
Battery Life Approx. 150hr
Clamp opening size 25mm
CT Diameter size 29mm
Dimension (L x W x H) 193 x 50 x 28mm, 7.60 x 1.97 x 1.1inch
Weight 230g, 8.11OZ (include battery)
Accessory Instruction Manual, Carrying case, Test lead, Battery 1.5V x 2



The accuracy specification is defined as
±(...%reading+...count)
At 23
±5°C, over 80%RH

DCV (Autorange)

RangeRange

Resolution

Accuracy

Input
Impedance

Overload
Protection

400V

0.1V

1%rdg
+2dgt

1MW

660Vrms

600V

1V

ACV (Autorange)

Range

Resolution

Accuracy

Input
Impedance

Overload
Protection

50Hz~500Hz

400V

0.1V

1.5%rdg
+5dgt

1MW

660Vrms

600V

1V

ACA (Autorange)

Range

Resolution

Accuracy

Overload
Protection

40A

0.01A

50Hz~60Hz

60Hz~500Hz

600Arms

400A

0.1A

1.9%rdg
+5dgt

2.5%+5dgt

Ohm (W)

Range

Resolution

Accuracy

MAX Test
Voltage

Overload
Protection

400W

0.1W

1%rdg
+2dgt

1.5VDC

600Arms

Continuity

Range

< 40 Ohm

MAX Test
Voltage

Overload
Protection

1.5VDC

600Vrms

Frequency (Hz) (Autorange)

Function

Range

Resolution

Accuracy

Sensitivity

Overload
Protection

Current
Frequency

20Hz~4kHz

1Hz

0.1%rdg
+1dgt

2Arms

600Arms

10kHz

10Hz

Voltage
Frequency

4kHz

1Hz

0.1%rdg
+1dgt

3Vrms

600Vrms

40kHz

10Hz

400kHz

100Hz

4MHz

1kHz

5Vrms

10MHz

10kHz

Home     |     About Us     |    Products     |    Telecom Systems    |    Contact Us    |    E-mail


Bhumika International Inc.
Ph: +1(416) 930 2931
E-mail: info@bhumika.ca
Website: http://www.bhumika.ca

Technical Specifications are subject to change without notice.
Windows is the registered Trademark of Microsoft Corporation, USA.
All other trademarks are the ownership of their respective owners.