Photo:DG525


These instruments are compact, handy high-performance digital insulation tester with an additional AC voltage measuring function.
DG525 & DG251 are in compliance with JIS C1302 1994.




1. Each instrument is capable of switching the test voltages during insulation resistance measurement in the following 2 ranges.
Model DG525 : 500V DC/250V DC
Model DG251 : 250V DC/125V DC
2. With both measuring functions, range can be shifted to the optimize range according to the measurement value.
3. The auto power OFF turns the power off automatically in about 1 minute after power on even when the user forgets to switch the power off after measurement.
4. Backlight in provided for easy readout, even in the dark.
5. The data hold feature holds the measurement value.
6. When the built-in batteries run out, the battery alarm display indicates battery replacement timing.




1. TL-M54 (Test Probe) Red test lead with amber plug (L/ ~ terminal) x 1
Black test lead with black plug (E/ ~ terminal) x 1
2. Instruction manual x 1
3. Battery 1.5V AA x 6




A/D Converter: Operating system: Double integration
Sampling rate: Approx. 2.5samplings/sec.
Display: LCD, max. 1999
Over-input indication: Only the highest digit shows "1".
Measuring terminals: MW: E, L ACV: ~, ~
Operating temperature
/humidity range:
0 ~ 40șC, <85% RH (with no condensation)
Accuracy guaranteed temperature
/humidity range:
15 ~ 30șC, <85% RH (with no condensation)
Built-in batteries: 1.5V LR6/AA size alkaline batteries (x 6)
Battery life: When power is switched between ON and OFF every minute in succession, Insulation resistance measurement: Approx. 60 hours
AC voltage measurement: Approx. 250hours
Battery alarm: LCD shows "B" marking when battery voltage drops below 7V.
Auto power OFF time: Approx. 1 minute after power ON
Data hold: Pressing HOLD switch holds measurement value.
Data hold indicator:Yellow LED with 3mm dia.
Back-light lamp: Pressing LIGHT switch lights up LCD backlight (green).
Dimensions & weight: 175 x 115 x 55mm. approx. 0.6kgs.

* when indicating the center scale value of the MW range



Insulation Resistance

Rated voltage DG525 500V DC/250V DC
DG251 250V DC/125V DC
Measuring voltage
/current characteristics
When measuring terminals are open,
DG525 500V DC range --- 600V (+20%max)
> 500V guaranteed at 500k
W
250V DC range --- 300V (+20%max)
> 250V guaranteed at 250k
W
DG251 250V DC range --- 300V (+20%max)
> 250V guaranteed at 250k
W
125V DC range --- 150V (+20%max)
> 125V guaranteed at 125k
W
When measuring terminals are shorted, Approx. 1.5mA max.
Measuring ranges 0~2MW/1~20MW/10~200MW/100~2000MW, auto range
Measuring accuracy 2MW/20MW/200MW ranges: Within(2% of reading+2digits)
2000M
W range: Within(5% of reading+2digits)
Applied voltage indication Red LED with 5mm dia.


AC Voltage

Measuring ranges 0 ~ 600V max.
0 ~ 200V /10 ~ 600V, 2 auto range
Measuring accuracy Within ±(1% of reading+0.5% of range + 1digit)
Frequency: 50~400Hz
Input resistance 1MW

Home     |     About Us     |    Products     |    Telecom Systems    |    Contact Us    |    E-mail


Bhumika Enterprises
1301  Dundas Street West, Suite # 504,
Mississauga, Ontario, L5C 1C9, Canada

Ph: +1(
647) 273 1281
FAX: +1(905) 615 9646

E-mail: info@bhumika.ca
Website: http://www.bhumika.ca

Technical Specifications are subject to change without notice.
Windows is the registered Trademark of Microsoft Corporation, USA.