Electronic Power- and Energy Meters for Panel and Rail Mounting

Typical Applications:
Power- and energy metering, energy management and process control in buildings and plants
 
  • Multifunctional - All electrical values for power consumption
  • Per phase and totals of kW, kvar, V, A, PF (power factor)
  • Backlighted displays
  • High accuracies 0,2%
  • Alarm outputs, analog outputs
  • PC Interfaces RS422/485 or RS232
 
  Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
PM303D8/kWh Cube PM303d8 kWh / kW Meter kWh metering in control panels,
Energy management,
Panel mounting
1 or 3 Phases
Volt & Amp
kWh,
(kW for 1 minute)
Cl. 1 kWh
Cl. 0.5
No 0 standard,
1 resp. 2 Pulse as option
Panel
96x96x80mm
  Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
RM303D8/PowerRail 303 RM303d8 kWh / kW Meter kWh metering in control panels,
Energy Management,
Rail Mounting
1 or 3 Phases,
Volt & Amp
kWh kWh,
(kW for 1 minute)
Cl. 1 kWh No 1 Pulse Rail
6 units
106x90x58mm
  Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
RM323/PowerRail323 RM323 kW, kWDemand & kWh Meter Energy management,
Control panels requiring kWh & kW MD,
Rail Mounting
3 Phases,
Volt & Amp
kW, kW MD,
kWh
Cl. 1 kWh RS485/
RS422
with Option- Modul
1 Pulse/
2 Analog with Option-Modul
Rail
6 units
106x90x58mm
  Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
Modbus Modul Modbus
Modul for RM323
(as Option)
Modbus interface and 2 analog outputs Process control,
Energy management
External supply Ref. RM323 Ref. RM323 RS422/RS485 2 Analog Rail
4 units
71x90x58mm
  Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
PM325/PowerCube PM325 kW, kW Demand & kWh Meter Energy management,
Control panels requiring kWh & kW MD,
Panel mounting
3 Phases
Volt & Amp
KW, kW MD,
kWh
Cl. 1 kWh RS485 1 Pulse as standard,
1 pulse as option
Panel
96x96x80mm
  Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
PM305 PM305-1 PM305-1
kW & kWh Meter
Energy management
Control panels requiring kWh & kW
3 Phases,
Volt & Amp
kW & kWh,
per Phase kW & PF
Cl. 1 kWh No 2 Pulse/ Alarm,
4-20mA
Panel
96x48x80mm
Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
PM305-2 PM305-2
Energy Meter
Energy management needing kVAh/kvarh in addition to kWh,
Control panels requiring measurement of all energies
3 Phases,
Volt & Amp
kW, kVA, kvar & Hz,
kWh, kVAh, kvarh,
per Phase kW & PF
Cl. 1 kWh
Cl. 3 kvarh
RS485/
RS422

RS232
2 Pulse/ Alarm,
4-20mA
Panel
96x48x80mm
Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
PM305-3 PM305-3
All Function (Multifunction) Meter
Energy management needing kVAh/kvarh in addition to kWh plus Volts & Amps,
Control panels requiring measurement of all energies plus Volts & Amps.
3 Phases,
Volt & Amp
kW, kVA, kvar, PF & Hz,
kWh, kVAh, kvarh
Volt, Amp,
per Phase kW & PF
Cl. 1 kWh
Cl. 3 kvarh
RS485/
RS422

RS232
2 Pulse/ Alarm,
4-20mA
Panel
96x48x80mm
Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
PM305-4 PM305-4
kW & kWh Meter with Volts & Amps
Control panels requiring measurement of kWh plus Volt & Amps,
kW also available,
Energy management
3 Phases,
Volt & Amp
PF, kW, kWh,
Volt, Amp & Hz,
per Phase kW & PF
Cl. 1 kWh RS485/
RS422

RS232
2 Pulse/ Alarm,
4-20mA
Panel
96x48x80mm
  Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
PM305 PM305-5 PM305-5
Energy and
MD Meter
Energy management needing kVAh/kvarh,
Control panels requiring measurement of all energies,
in both cases with kW & kVA MD
3 Phases,
Volt & Amp
kW, kVA, kvar, PF & Hz.  RTC,
kWh, kVAh, kvarh,
per Phase kW & PF,
kW & kVA MD
Cl. 1 kWh
Cl. 3 kvarh
RS485/
RS422

RS232
2 Pulse/ Alarm,
4-20mA
Panel
96x48x80mm
Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
PM305-6 PM305-6
All Function (Multifunction) MD Meter
Energy management needing kVAh/kvarh,
Control panels requiring measurement of all energies,
in both cases with Volt & Amps measurement and kW & kVA MD
3 Phases,
Volt & Amp
kW, kVA, kvar, PF & Hz.  RTC,
kWh, kVAh, kvarh,
Volt, Amp
per Phase kW & PF,
kW & kVA MD
Cl. 1 kWh
Cl. 3 kvarh
RS485/
RS422

RS232
2 Pulse/ Alarm,
4-20mA
Panel
96x48x80mm
Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
PM305-7 PM305-7 Import/Export Energy Meter Energy management needing kVAh/kvarh,
Control panels requiring measurement of all energies,
in both cases both import & export energies
3 Phases,
Volt & Amp
kW, kVA, kvar, PF & Hz,
kWh, kVAh, kvarh,
per Phase kW & PF
Cl. 1 kWh
Cl. 3 kvarh
RS485 2 Pulse/ Alarm,
4-20mA
Panel
96x48x80mm
Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
PM305-8 PM305-8
All Function (Multifunction) Import/Export Meter
Energy management needing kVAh/kvarh,
Control panels requiring measurement of all Energies,
in both cases with Volt & Amps measurement and both import & export energies
3 Phases,
Volt & Amp
kW, kVA, kvar, PF & Hz,
kWh, kVAh, kvarh,
Volt, Amp,
per Phase kW & PF
Cl. 1 kWh
Cl. 3 kvarh
RS485/
RS422

RS232
2 Pulse/ Alarm,
4-20mA
Panel
96x48x80mm
  Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
PM390 PM390 PM390 Multifunction Meter Control panels requiring a high accuracy unit to replace all panel indicators & energy meters,
import & export energies measured
3 Phases,
Volt & Amp
kW, kVA, kvar, PF & Hz,
Volt & Amp,
Peak V & I,
kWh, kVAh, kvarh,
per Phase kW, kVA, kvar & PF
Cl. 0.5 kWh
Cl. 1 kvarh
RS485/
RS422

RS232
2 Pulse/ Alarm,
4-20mA
Panel
96x96x80mm
Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
PM390MD PM390 Multifunction Maximum Demand Meter Control panels requiring a high accuracy unit to replace all panel indicators & energy meters, and an MD indicator,
import & export energies measured
3 Phases,
Volt & Amp
kW, kVA, kvar, PF & Hz;  Volt & Amp,
Peak V & I, RTC,
kWh, kVAh, kvarh,
per Phase kW , kVA, kvar & PF,
kW & kVA MD
Cl. 0.5 kWh
Cl. 1 kvarh
RS485/
RS422

RS232
2 Pulse/ Alarm,
4-20mA
Panel
96x96x80mm
  Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
PM380 PM380-1 Panel Indicator Control panels - replacement for Volt, Amp, kW, PF & frequency indicators 3 Phases,
Volt & Amp
Per Phase V, I, kW & PF,
3 Phase kW, PF & Hz
±0.2% V & I
±0.4% Watt
RS485 None Panel
96x96x80mm
Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
PM380-2 Indicator & Meter Control panels - replacement for Volt, Amp, kW, PF & frequency indicators plus kWh meter 3 Phases,
Volt & Amp
Per Phase V, I, kW & PF, kWh
3 Phase kW, PF & Hz.
Cl.1 kWh RS485 1 Pulse Panel
96x96x80mm
Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
PM380-3 Indicator & Meter Control panels - replacement for Volt, Amp, kW, kvar, PF & frequency indicators, kW demand meter plus kWh & kvarh meters 3 Phases,
Volt & Amp
Per Phase V, I, kW, kvar & PF,
3 Phase kW, kvar, PF & Hz.   kW MD
kWh & kvarh
Cl.1 kWh
Cl. 2 kvarh
RS485 2 Pulse Panel
96x96x80mm
Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
PM380-4 Indicator & Meter Control panels - replacement for Volt, Amp, kW, kVA, kvar, PF, frequency & neutral current indicators, kW demand meter plus kWh & kvarh meters 3 Phases,
Volt & Amp
Per Phase V, I, kW, kVA, kvar & PF,
3 Phase kW, kVA, kvar, PF & Hz.   kW MD,
kWh & kvarh,
ceutral current,
peak V & I
Cl.1 kWh
Cl. 2 kvarh
RS485 2 Pulse Panel
96x96x80mm
  Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
PM380 PM380-9.1 Indicator & Meter for Import and Export Control panels - replacement for Volt, Amp, kW, PF & frequency indicators 3 Phases,
Volt & Amp
Per Phase V, I, kW & PF,
3 Phase kW, PF & Hz
±0.2% V & I
±0.4% Watt
RS485 None Panel
96x96x80mm
Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
PM380-9.2 Indicator & Meter for Import and Export Control panels - replacement for Volt, Amp, kW, PF & frequency indicators plus kWh meter 3 Phases,
Volt & Amp
Per Phase V, I, kW & PF, kWh
3 Phase kW, PF & Hz,
import energy KWh
Cl.1 kWh RS485 1 Pulse Panel
96x96x80mm
Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
PM380-9.3 Indicator & Meter for Import and Export Control panels - replacement for Volt, Amp, kW, kvar, PF & frequency indicators, kW demand meter plus kWh & kvarh meters 3 Phases,
Volt & Amp
Per Phase V, I, kW, kvar & PF,
3 Phase kW, kvar, PF & Hz, 
kW MD,
kWh & kvarh, import energy KWh
Cl.1 kWh
Cl. 2 kvarh
RS485 2 Pulse Panel
96x96x80mm
Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
PM380-9.4 Indicator & Meter for Import and Export 3 Phase Volt & Amp 3 Phases,
Volt & Amp
Per Phase V, I, kW, kVA, kvar & PF,
3 Phase kW, kVA, kvar, PF & Hz,
kW MD,
kWh & kvarh,
neutral current,
peak V & import and export energy KWh
RS485 2 Pulse Panel
96x96x80mm
 
  Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
MultiCube Option Modul Multicube Option-Modul Modbus Interface Process control,
Energy management
Ref. PM380 Ref. PM380   RS422/ RS485, external supply needed No Sticked on the rear of the PM380
Multicube Option-Modul Fourfold Analog Output Process control,
Energy management
Ref. PM380 Ref. PM380   no 4 Analog Sticked on the rear of the PM380
  Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
Rail RTU RAIL RTU Multifunctional,
Registration of harmonic distortion,
For system use,
Display just adress and baud rate
Process control,
Energy management
3 Phases,
Volt & Amp
per Phase Volt, Amp, kW, kVA, kvar, PF
3 Phase kW, kVA, kvar, PF, Hz, neutral current, harmonic distortion
±0.2% U/I
±0.4% W
RS485 Modbus 2 Pulse optional Rail Mounting
6 units
  Model Description Application Inputs Meas. Values Accuracy Interfaces Outputs Form Factor
MultiRail Multi RAIL Multifunctional,
Registration of harmonic distortion,
For system use,
Display for all values
Process control,
Energy management
3 Phases,
Volt & Amp
per Phase Volt, Amp, kW, kVA, kvar, PF
3 Phase kW, kVA, kvar, PF, Hz, neutral current, harmonic distortion
±0.2% U/I
±0.4% W
RS485 Modbus 2 Pulse optional Rail Mounting
6 units
 
 

Home     |     About Us     |    Products     |    Telecom Systems    |    Contact Us    |    E-mail


Bhumika International Inc.
804 - 2770 Aquitaine Avenue
Mississauga, Ontario, L5N 3K5, Canada
Ph: +1(416) 930 2931, E-mail: info@bhumika.ca  