Category
Digital Multimeters
SANWA digital multimeters provide model-specific electrical measurement functions for users comparing compact meters, dual displays and PC Link. Bhumika is SANWA’s authorized Canadian distributor and provides quotes for Canada.
Which digital multimeters does Bhumika supply?
SANWAPC7000SANWA PC7000 Digital MultimeterDual-display True RMS multimeter with optional PC Link.
- True RMS
- CAT III 600 V
- PC Link
SANWACD5001SANWA CD5001 Digital MultimeterVoltage-focused True RMS meter with no current ranges.
- CAT IV 600 V
- True RMS
- 9999 count
SANWACD5002SANWA CD5002 Digital MultimeterCompact meter with DC/AC current, Auto Hold and backlight.
- CAT IV 600 V
- True RMS
- 9999 count
SANWACD800a3SANWA CD800a3 Digital Multimeter6000-count True RMS multimeter with EF sensing.
- CAT IV 600 V
- True RMS
- 6000 count
SANWAPC700SANWA PC700 Digital MultimeterDual-display multimeter with PC Link and 0.06% best accuracy.
- Dual display
- PC Link
- 0.06% accuracy
SANWACD5003SANWA CD5003 Digital MultimeterCompact True RMS meter with low-pass filter and DC+AC voltage.
- CAT IV 600 V
- True RMS
- Low-pass filter
SANWACD800a2SANWA CD800a2 Digital Multimeter6000-count True RMS ALL-IN-ONE meter with protective body cover.
- CAT IV 600 V
- True RMS
- 6000 count
SANWACD800aSANWA CD800a Digital Multimeter4000-count ALL-IN-ONE meter with protective body cover.
- 4000 count
- 0.7% accuracy
- Low power ohm
SANWAPC710SANWA PC710 Digital MultimeterTrue RMS dual-display meter with capture, EF detection and temperature probe.
- True RMS
- Dual display
- CAT III 600 V
SANWAPC720MSANWA PC720M Digital MultimeterHigh-accuracy dual-display meter with 87,382-point built-in logging.
- 87,382-point log
- ±0.06% DCV
- CAT III 600 V
SANWAPC773SANWA PC773 Digital Multimeter11,000-count meter with 11 A current range and PC connection.
- 11000 count
- ±0.28% DCV
- 11 A
SANWAPC20SANWA PC20 Digital Multimeter4000-count meter with AC adapter input for long-duration measurement.
- 4000 count
- ±0.5% DCV
- AC adapter input
SANWACD770SANWA CD770 Digital Multimeter4000-count standard meter with capacitance and frequency.
- 4000 count
- Capacitance
- Frequency
SANWACD771SANWA CD771 Digital MultimeterBacklit 4000-count meter with LED continuity and 30 kA fuses.
- Backlight
- 30 kA fuses
- Current to 10 A
SANWACD772SANWA CD772 Digital MultimeterTrue RMS 4000-count meter with K-type temperature measurement.
- True RMS
- K-type −20–300 °C
- Backlight
SANWARD700SANWA RD700 Digital Multimeter4000-count meter with 1000 MΩ input impedance and K-type temperature.
- 1000 MΩ input
- ±0.3% DCV
- K-type temperature
SANWARD701SANWA RD701 Digital Multimeter4000-count meter with 1000 MΩ input impedance and K-type temperature.
- 1000 MΩ input
- ±0.3% DCV
- K-type temperature
SANWACD732SANWA CD732 Digital Multimeter6000-count meter with wide capacitance range and LED continuity.
- 6000 count
- 61-segment bar graph
- Cap. to 3999 µF
SANWAPM3SANWA PM3 Digital MultimeterUltra-slim pocket meter with capacitance and frequency.
- CAT III 300 V
- 4000 count
- Approx. 50 g
SANWAPM7aSANWA PM7a Digital MultimeterPocket digital multimeter with integrated protective case.
- 4000 count
- ±0.7% DCV
- Approx. 85 g
SANWAPM11SANWA PM11 Digital MultimeterPocket meter with analog bar graph and one-hand lead fixing.
- 4000 count
- ±0.8% DCV
- Bar graph
SANWAPM33aSANWA PM33a Digital MultimeterPocket DMM combined with a 100 A clamp sensor.
- 100 A DC/AC
- 6600 count
- Approx. 160 g
Compare models
Figures are shown only where SANWA publishes them. “Not stated” means SANWA does not publish a figure for that model — it does not mean the instrument lacks the capability.
| Model | Display | DCV accuracy | True RMS | Safety | Power |
|---|---|---|---|---|---|
| PC7000 | 50,000 count (500,000 for DC voltage); dual display; 41-segment bar graph | ±(0.03%+2) | Yes | IEC 61010 CAT III 600 V | 9 V ×1; approx. 100 h |
| CD5001 | 9999 count | ±(0.5%+2) | Yes | CAT IV 600 V / CAT III 1000 V | LR03 ×2; approx. 550 h |
| CD5002 | numeral display 9999 | ±(0.5%+2) | Yes | CAT IV 600 V / CAT III 1000 V | LR03x2 |
| CD800a3 | numeral display 6000/9999(Hz function) | ±(0.7%+3) | Yes | IEC 61010 CAT IV 600 V | R6x2 |
| PC700 | 6000 & 9999 counts; dual display; 41-segment bar graph | ±(0.06%+2) | Not stated | IEC 61010 CAT III 600 V | 6F22(9V)×1 |
| CD5003 | numeral display 9999 | ±(0.3%+5) | Yes | CAT IV 600 V | LR03x2 |
| CD800a2 | numeral display 6000/9999(Hz function) | ±(0.7%+3) | Yes | IEC 61010 CAT IV 600 V | R6x2 |
| CD800a | numeral display 4000 | ±(0.7%+3) | Not stated | Not stated | R6P(1.5V)x2 |
| PC710 | numeral display 9999 & 6000, bar graph 41 segments | ±(0.06%+2) | Yes | IEC 61010 CAT III 600 V | 6F22(9V)x1 |
| PC720M | numeral display 9999 & 6000 Bar graph 41 segments | ±(0.06%+2) | Not stated | IEC 61010 CAT III 600 V | 6LR61(9V)x1 |
| PC773 | numeral display 11000 | ±(0.28%+2) | Not stated | Not stated | R6x2 |
| PC20 | numeral display 4000 | ±(0.5%+2) | Not stated | Not stated | R6x2 |
| CD770 | numeral display 4000 | ±(0.5%+2) | Not stated | Not stated | R6Px2 |
| CD771 | numeral display 4000 | ±(0.5%+2) | Not stated | Not stated | R6Px2 |
| CD772 | numeral display 4000 | ±(0.5%+2) | Yes | Not stated | R6Px2 |
| RD700 | numeral display 4000(Hz:9999, capacitance:5000) | ±(0.3%+4) | Not stated | Not stated | 6F22(9V)×1 |
| RD701 | numeral display 4000(Hz:9999, capacitance:5000) | ±(0.3%+4) | Not stated | Not stated | 6F22(9V)×1 |
| CD732 | numeral display 6000 bar graph 61 segments | ±(0.5%+2) | Not stated | Not stated | R6(1.5V)x2 |
| PM3 | numeral display 4000 | ±(0.7%+3) | Not stated | IEC 61010 CAT III 300 V | Coin type lithium battery CR2032(3V)x1 |
| PM7a | numeral display 4000 | ±(0.7%+3) | Not stated | Not stated | Button battery LR-44x2 |
| PM11 | numeral display 4000, bar graph 40 segments | ±(0.8%+4) | Not stated | Not stated | Button battery LR-44X2 |
| PM33a | numeral display 6600 | ±(0.7%+3) | Not stated | Not stated | LR03×2 |
What should I consider before buying?
CD5001 has no current ranges; CD5002 adds DC/AC current measurement and temperature measurement with an optional probe. PC7000 lists a VFD low-pass filter, 0.8 ms capture/peak hold and PC Link via optional KB-USB7. CD800a3 includes EF sensing and a backlight.
What do buyers usually ask?
What safety ratings are listed for CD5001 and CD5002?
Both list CAT IV 600 V / CAT III 1000 V. These are the stated category and voltage ratings for these models.
Does CD5001 measure current?
No. CD5001 has no current ranges; CD5002 lists DC/AC current measurement.
What is needed for PC7000 PC Link?
PC7000 supports PC Link through the optional KB-USB7.