Category
Clamp Meters
SANWA clamp meters measure current without breaking the circuit, from 120 g pocket AC models to DC/AC meters rated to 2000 A and a flexible CT reaching 3000 A. Most add voltage, resistance and DMM functions. Bhumika is SANWA’s authorized Canadian distributor and provides quotes for Canada.
Which clamp meters does Bhumika supply?
SANWADCM401SANWA DCM401 Clamp MeterDC/AC True RMS clamp to 1000 A with EF detection and LoZ voltage.
- 1000 A DC/AC
- CAT IV 600 V
- LoZ voltage
SANWADCM301SANWA DCM301 Clamp MeterAC True RMS clamp to 1000 A with EF detection and DC voltage.
- 1000 A AC
- CAT IV 600 V
- EF detection
SANWADLC470SANWA DLC470 Leakage Clamp MeterLeakage clamp with 0.01 mA resolution and band-pass filter.
- 0.01 mA leakage
- 400 A AC
- CAT III 600 V
SANWADCM400SANWA DCM400 Clamp MeterLow-cost AC clamp to 400 A with DMM functions and bar graph.
- 400 A AC
- CAT III 300 V
- Bar graph
SANWADCL1000SANWA DCL1000 Clamp MeterLarge-jaw AC clamp to 1000 A at about 290 g.
- 1000 A AC
- Φ42 mm jaw
- Approx. 290 g
SANWADCM400ADSANWA DCM400AD Clamp MeterSlim DC/AC clamp to 400 A aimed at automotive maintenance.
- 400 A DC/AC
- CAT III 300 V
- Automotive
SANWADCL11RSANWA DCL11R Mini Clamp MeterPocket True RMS AC clamp to 300 A at about 120 g.
- 300 A AC
- Pocket size
- Approx. 120 g
SANWADCM60RSANWA DCM60R Clamp MeterCompact True RMS AC clamp to 600 A with voltage and resistance.
- 600 A AC
- True RMS
- CAT III 300 V
SANWADCM660RSANWA DCM660R Clamp MeterTrue RMS AC clamp to 660 A with inrush current and MAX/MIN.
- 660 A AC
- Inrush current
- CAT III 600 V
SANWADCL1200RSANWA DCL1200R Clamp MeterLarge-jaw True RMS AC clamp to 1200 A with auto V/Ω detection.
- 1200 A AC
- Φ42 mm jaw
- Auto V/Ω
SANWADCL3000RSANWA DCL3000R Flexible-CT Clamp MeterFlexible AC current sensor to 3000 A with MAX/MIN hold.
- 3000 A AC
- Flexible CT
- CAT IV 600 V
SANWADCL31DRSANWA DCL31DR Mini Clamp MeterPocket DC/AC True RMS clamp to 400 A with peak hold.
- 400 A DC/AC
- Peak hold
- Pocket size
SANWADCM600DRSANWA DCM600DR Clamp MeterDC/AC True RMS clamp to 600 A with 1 ms peak hold for vehicle work.
- 600 A DC/AC
- 1 ms peak hold
- CAT III 600 V
SANWADCM2000DRSANWA DCM2000DR Clamp MeterFlagship DC/AC clamp to 2000 A, CAT IV 1000 V, dual display.
- 2000 A DC/AC
- CAT IV 1000 V
- Dual display
Compare models
Figures are shown only where SANWA publishes them. “Not stated” means SANWA does not publish a figure for that model — it does not mean the instrument lacks the capability.
| Model | Display | AC current range | AC current accuracy | Safety | Clamp diameter |
|---|---|---|---|---|---|
| DCM401 | 6000 counts (9999 on Hz function) | 60.00 / 600.0 / 1000 A | ±(2.5%+5) | IEC61010 CAT. IV 600 V / CAT. III 1000 V | Φ34 mm / 10 × 64 mm |
| DCM301 | 6000 counts (9999 on Hz function) | 60.00 / 600.0 / 1000 A | ±(2.5%+5) | IEC61010 CAT. IV 600 V / CAT. III 1000 V | Φ34 mm / 10 × 64 mm |
| DLC470 | 6000 (A/V); 9999 (Ω) | 60.00 A / 400.0 A | ±(1.2%+5) | IEC61010 CAT. III 600 V | Φ35 mm / 10 × 40 mm |
| DCM400 | 4000 counts | 40 / 400 A | ±(1.9%+5) | IEC61010 CAT. III 300 V | Φ25 mm / 10 × 34 mm |
| DCL1000 | 4000 counts | 400 / 1000 A | ±(1.7%+5) | Not stated | Φ42 mm / 20 × 54 mm |
| DCM400AD | 4000 counts | 40 / 400 A | ±(2%±10) | IEC61010 CAT. III 300 V | Φ25 mm / 10 × 34 mm |
| DCL11R | 6000 counts | 60 / 300 A | ±(2.0%+5) | IEC61010 CAT. III 300 V | Φ22 mm / 10 × 25 mm |
| DCM60R | 1999 counts | 199.9 / 600 A | ±(2.0%+5) | IEC61010 CAT. III 300 V | Φ25 mm / 10 × 30 mm |
| DCM660R | 6600 counts | 66 / 660 A | ±(2%+5) | IEC61010 CAT. III 600 V | Φ30 mm / 10 × 50 mm |
| DCL1200R | 6000 counts | 400 / 1200 A | ±(1.7%+5) | Not stated | Φ42 mm / 20 × 54 mm |
| DCL3000R | 3150 counts | 30 / 300 / 3000 A | ±(3.0%+5) | IEC61010 CAT. IV 600 V | Approx. Φ150 mm max. |
| DCL31DR | 6000 counts | 60 / 400 A | ±(2.0%+5) | IEC61010 CAT. III 300 V | 25 mm / 10 × 26 mm |
| DCM600DR | 6000 counts | 60 / 600 A | ±(2%+5) | IEC61010 CAT. III 600 V | Φ30 mm / 10 × 50 mm |
| DCM2000DR | 6000 counts (1999 on Hz) | 200.0 / 2000 A | ±(2.0%+5) | IEC61010 CAT. IV 1000 V | Φ55 mm / 20 × 66 mm |
What should I consider before buying?
Decide first whether you need DC current: DCM401, DCM400AD, DCL31DR, DCM600DR and DCM2000DR measure DC and AC, while the rest are AC-only. For CAT IV, DCM401 and DCM301 list CAT IV 600 V / CAT III 1000 V, DCM2000DR lists CAT IV 1000 V and DCL3000R lists CAT IV 600 V. DLC470 is the leakage specialist with 0.01 mA resolution, DCL1000 and DCL1200R have a Φ42 mm jaw, and DCL3000R uses a flexible CT. DCM660R measures inrush current; DCM600DR and DCM2000DR have peak hold.
What do buyers usually ask?
Which clamp meters measure DC current?
DCM401, DCM400AD, DCL31DR, DCM600DR and DCM2000DR measure both DC and AC current. The other models in the range are AC-only.
Which model is for leakage current?
DLC470 measures AC leakage current in 60.00 mA and 600.0 mA ranges with 0.01 mA resolution, with a band-pass filter that extracts mainly the 50/60 Hz component.
What is the largest current range?
DCL3000R measures AC current to 3000 A with a flexible CT. DCM2000DR measures DC and AC current to 2000 A and is rated CAT IV 1000 V.