Leakage clamp with 0.01 mA resolution and band-pass filter.

  • 0.01 mA leakage
  • 400 A AC
  • CAT III 600 V

The SANWA DLC470 is a multifunction leakage clamp meter for users measuring small AC leakage currents in milliamps. A band-pass filter extracts mainly the 50/60 Hz component, and MAX/MIN hold records the extremes. It also measures AC current to 400 A, voltage and resistance. Bhumika quotes this model for Canada.

View quote basket

SANWA DLC470 leakage clamp meter

Features

  • Leakage current (ACmA) with 0.01 mA resolution
  • Band-pass filter (BPF) extracts mainly the 50/60 Hz component
  • MAX/MIN value hold
  • Auto power off (30 min., cancelable)
  • AC current to 400 A, plus voltage, resistance and continuity

Specifications

Measurement
AC leakage current60.00 mA / 600.0 mA; ±(1.2%+5); resolution 0.01 mA
AC current60.00 A / 400.0 A; ±(1.2%+5); resolution 0.01 A
AC voltage600.0 V; ±(1.2%+5); resolution 0.1 V
DC voltage600.0 V; ±(1.0%+2); resolution 0.1 V
Resistance999.9 Ω; ±(1.0%+8); resolution 0.1 Ω
Display & Functions
ContinuityBuzzer sounds at 30 Ω or below; open voltage approx. 0.9 V
Display6000 (A/V); 9999 (Ω)
Sampling rate2 times/sec.
Bandwidth40–400 Hz
Safety
RatingIEC61010 CAT. III 600 V
Power & Physical
Clamp diameter / conductor sizeΦ35 mm / 10 × 40 mm
BatteryLR03 × 2
Battery lifeApprox. 42 hrs. (alkaline battery, backlight off)
DimensionsH206 × W83 × D38 mm
MassApprox. 320 g

Standard accessories

  • TL-21a test lead
  • C-DCM660 carrying case

Optional accessories

  • CL-14 adapter
  • CL-15a adapter
  • TL-9IC adapter
  • CL-DG3a adapter
  • TL-A7M2 adapter