SANWA · Clamp Meters
DCM2000DR
Flagship DC/AC clamp to 2000 A, CAT IV 1000 V, dual display.
- 2000 A DC/AC
- CAT IV 1000 V
- Dual display
The SANWA DCM2000DR is SANWA's flagship clamp meter in this range: DC and AC current to 2000 A in a CAT IV 1000 V body. A dual display shows voltage or current together with frequency, and VFD frequency measurement, a low-pass filter, EF detection and a low-impedance voltage range suit drive and ghost-voltage work. Bhumika quotes this model for Canada.

Features
- DC and AC current to 2000 A, True RMS
- CAT IV 1000 V
- Dual display: voltage/current and its frequency
- VFD (variable frequency drive) frequency measurement
- Low-pass filter
- EF detection; low-input-impedance voltage to attenuate ghost voltages
- Peak hold with 5 ms interval
- Auto selection of DCV / ACV / Ω
- Auto power save (30 min., cancelable)
Specifications
| AC current | 200.0 / 2000 A; ±(2.0%+5); resolution 0.1 A |
|---|---|
| DC current | 200.0 / 2000 A; ±(2.0%+5); resolution 0.1 A |
| AC voltage | 6.000 / 60.00 / 600.0 / 1000 V; ±(1.2%+5); resolution 0.001 V |
| DC voltage | 6.000 / 60.00 / 600.0 / 1000 V; ±(0.5%+5); resolution 0.001 V |
| Resistance | 600.0 / 6.000k / 60.00k / 600.0k / 6.000M / 40.00 MΩ; ±(0.5%+5); resolution 0.1 Ω |
| Frequency | 10–1999 Hz; ±(0.1%+4); resolution 0.01 Hz |
| Capacitance | 60n / 600n / 6µ / 60µ / 600µ / 2000 µF; ±(2.0%+5); resolution 0.01 nF |
| Continuity | Buzzer sounds below 10–200 Ω; open voltage approx. 0.5 V |
|---|---|
| Diode test | Open voltage approx. 1.8 V |
| EF sensing | Detects a voltage or electric field of approx. 60 V or more; bar graph and intermittent beeps change in three steps with field intensity (50/60 Hz) |
| Display | 6000 counts (1999 on Hz) |
| Sampling rate | Approx. 5 times/sec. |
| Bandwidth | 50–400 Hz |
| Max. overload protection input | DC/AC 1100 V; CT: DC/AC 2000 A |
| Rating | IEC61010 CAT. IV 1000 V |
|---|
| Clamp diameter / conductor size | Φ55 mm / 20 × 66 mm |
|---|---|
| Battery | R6P × 2 |
| Battery life | A function: approx. 80 hrs.; other functions: approx. 240 hrs. (zinc-carbon battery, backlight off) |
| Dimensions | H264 × W97 × D43 mm |
| Mass | Approx. 640 g |
Standard accessories
- TL-29 test lead
- C-DCM2000DR carrying case